Synthetic absorbable:
--chromic/plain catgut
--polygycolic acid braided suture
--polydioxanone monofilament suture
--Polyglactine (rapid)

Non-absorbable:
--silk braided suture
--nylon monofilament suture
--polyester braided suture
--polypropylene monofilament suture.
  • 1) we supply various kinds of surgical suture include: 
    Synthetic absorbable:
    --chromic/plain catgut
    --polygycolic acid braided suture
    --polydioxanone monofilament suture
    --Polyglactine (rapid)

    Non-absorbable:
    --silk braided suture
    --nylon monofilament suture
    --polyester braided suture
    --polypropylene monofilament suture.

    2) Japanese nuture material.
    3) 420 JZ stainless steel material.
    4) Suture Needles:
        Shape: Straight,1/4 Circle, 3/8 Circle, 1/2 Circle, 5/8 Circle
        Point type: Taper point, Blunt Taper point, Tapercut, Cutting, Reverse Cutting, Micro-point Spatula
    5) Size: USP3~10/0

      Synthetic Absorbable Suture
    1 PLAIN CATGUT

    -Used in general closure, ophthalmology, urology, orthopedics, bowel, anastomosis, ligation, contra-indicated in cardiovascular and neurological tissue.
    -Features: 1. High knot tensile strength. 2. Tight knot. 3. Smooth suture. 4. Excellent usability.
    -Composition: Plain catgut.
    -Type of absorption: Enzymatic digestion complete from 90days.
    -Tensile strength: strength retention for at least 21 days.
    -Thread Colour: straw
    -Structure: Monofilament
    -Origin: Bovine serosa
    -Sizes available: USP6/0 (1metric) to USP 3 (7metric)
    -Sterilization: Gamma Radiation
    2 CHROMIC CATGUT

    -Used in general closure, ophthalmology, urology, urology, orthopedics, bowel, anastomosis, ligation, contra-indicated in cardiovascular and neurological tissue.
    -Features: 1. High knot tensile strength. 2. Tight knot. 3. Smooth suture. 4. Excellent usability.
    -Composition: Natural purified collagen.
    -Type of absorption: Enzymatic digestion complete from 90days.
    -Tensile strength: strength retention for up to 28days.
    -Thread Colour: brown & green
    -Structure: Monofilament
    -Origin: Bovine serosa
    -Sizes available: USP6/0 (1metric) to USP 3 (7metric)
    -Sterilization: Gamma Radiation
    3 POLYGLYCOLIC ACID BRAIDED

    -Used in general soft tissue approximation including ophthalmic surgery. Not indicated for cardiovascular and neurological tissue approximation.
    -Features: 1. Strong initial tensile strength; 2. Guaranteed support during serious injury; 3. Smooth penetration of tissue; 4. Simple to use; 5. Excellent bandaging performance; 6. Tight knots.
    -Composition: Polyglycolic acid
    -Coating: Coated with magnesium stearate
    -Type of absorption: Absorption by hydrolysis complete between56 & 70days. Always predicable and reliable.
    -Tensile strength: High initial strength and strength retention for up to 28days.
    -Thread Colour: Violet
    -Structure: Braided
    -Origin: Synthetic
    -Sizes available: USP10/0 (0. 2metric) to USP 2 (5metric)
    -Sterilization: Ethylene Oxide
    4 POLYGLACTINE BRAIDED

    -Used in general soft tissue approximation including ophthalmic surgery. Not indicated for cardiovascular and neuro-
    logical tissue approximation.
    -Features: 1. Strong initial tensile strength; 2. Guaranteed support during serious injury for up to 6 weeks; 3. Smooth penetration of tissue; 4. Simple to use; 5. Excellent bandaging performance; 6. Tight knots.
    -Composition: Polyglactine
    -Coating: Coated with magnesium stearate
    -Type of absorption: Absorption by hydrolysis complete between56 & 70days. Always predicable and reliable.
    -Tensile strength: High initial strength and strength retention for up to 28days.
    -Thread Colour: Violet
    -Structure: Braided
    -Origin: Synthetic
    -Sizes available: USP10/0 (0. 2metric) to USP 2 (5metric)
    -Sterilization: Ethylene Oxide
    5 POLYDIOXANONE MONOFILAMENT

    -Used in general soft tissue approximation including ophthalmic surgery. Not indicated for cardiovascular and neuro-
    logical tissue approximation.
    -Features: 1. Strong initial tensile strength; 2. Guaranteed support during serious injury for up to 6 weeks; 3. Smooth penetration of tissue; 4. Simple to use; 5. Excellent bandaging performance; 6. Tight knots.
    -Composition: Polydioxanone.
    -Coating: Coated with polydioxanone polymer.
    -Type of absorption: Absorption by hydrolysis complete between 180 and 210 days. Always predicable and reliable.
    -Tensile strength: High initial strength and strength retention for up to 56 days.
    -Thread Colour: Violet-undyed
    -Structure: Monofilament.
    -Origin: Synthetic
    -Sizes available: USP9/0 (0. 3metric) to USP 2 (5metric)
    -Sterilization: Ethylene Oxide
      Non-absorbable Suture
    6 SILK BRAIDED

    -Used in most of the corporal tissues as suture or ligature. Plastic and general surgery. Not used in biliary and urinary tracts or in the presence of infection.
    -Features: 1. Smooth penetration of tissue; 2. Simple to use; 3. Excellent usability; 4. Tight knots.
    -Composition: Natural silk.
    -Coating: Wax and Silicone.
    -Thread Colour: Black
    -Structure: Braided
    -Origin: Silkworm larval cocoons
    -Sizes available: USP10/0 (0. 2metric) to USP 2 (5metric)
    -Sterilization: Gamma Radiation
    7 NYLON MONOFILAMENT

    -Used in skin suture and plastic surgery.
    -Features: 1. Smooth penetration of tissue; 2. High knot tensile strength; 3. Excellent compatibility with tissues; 4. Tight knots.
    -Composition: polyamide.
    -Coating: Uncoated.
    -Thread Colour: Blue dyed & Black dyed.
    -Structure: Monofilament.
    -Origin: Synthetic
    -Sizes available: USP11/0 (0. 1metric) to USP 2 (5metric)
    -Sterilization: Gamma Radiation. 
    8 POLYPROPYLENE

    -Used in skin suture and plastic surgery.
    -Features: 1. Smooth penetration of tissue; 2. High knot tensile strength; 3. Excellent compatibility with tissues; 4. Long-term tensile resistance; 5. Best usability.
    -Composition: polypropylene.
    -Coating: Uncoated.
    -Thread Colour: Blue.
    -Structure: Monofilament.
    -Origin: Synthetic
    -Sizes available: USP10/0 (0. 2metric) to USP 1 (4metric)
    -Sterilization: Gamma Radiation. 
    9 POLYESTER

    -Used in most of the corporal tissues as suture or ligature. Plastic and general surgery. Not used in biliary and urinary tracts or in the presence of infection.
    -Features: 1. Long-term tensile resistance; 2. High knot tensile strength; 3. Excellent compatibility with tissues; 4. Tight knots.
    -Composition: Polyester.
    -Coating: Uncoated.
    -Thread Colour: Dyed Blue.
    -Structure: Braided.
    -Origin: Synthetic.
    -Sizes available: USP6/0 (0. 7metric) to USP 1 (4 metric)
    -Sterilization: Gamma Radiation

     

     